STANDBY GENERATOR ACCESSORIES
21 Light Remote Annunciator
Liquid-Cooled Generator Sets
Model 5465
Model 5466
Model 5464
DESCRIPTION
The Remote Annunciator Panel provides remote monitoring and
annunciation of up to 18 generator parameters using LED’s located on
the annunciator keypad. It also provides two system level warnings which
are System Ready and Communications OK.
The specific faults can be selected using either the DIP switches located
on the annunciator circuit board or through a computer via the RS232
connection on the circuit board.All relays are energized on power up and
open during a fault condition.
The Relay panel has up to 8 selectable functions on form A relays,
and multiple relay panels can be connected for all 18 generator
parameters.
Communication is via a RS485 serial data link and power is supplied by
the generator battery (+12 VDC or +24 VDC)
Note:These units are only compatible with the H-series generator
controller (70-150 kW)
ENVIRONMENTAL SPECIFICATIONS
Operating Temperature.......................................................................................................................................................................... -25 º C to 60 º C
Humidity............................................................................................................................................................................... 0 to 95% Non-Condensing
Power Supply..........................................................................................................................................................................................+12 or +24 VDC
Power Usage ............................................................................................................................................................................................ 6 Watts typical
Power Supply.......................................................................................................................................................................................Generator Battery
Communication Line..........................................................................................................................RS485 fully isolated twisted pair cable with shield
Maximum Cable Length.................................................................................................................................................................................... 4000 feet
Relay Output.............................................................................One NO contact (Engergized when annunciator is powered and no faults are present)
Relay Contact Rating..............................................................................................................................................................................30 VDC, 1 amp
|
Eizo Computer Monitor S2133 User Manual
ETA Systems Surge Protector ETA S20 User Manual
ETI Sound Systems INC DJ Equipment LHEC20 User Manual
Excalibur electronic Fan FN10 BB User Manual
Fluke Stereo Amplifier 5205A User Manual
Frigidaire Dishwasher FFBD2409L User Manual
Frigidaire Microwave Oven FGMO205K User Manual
GBC Binding Machine P70IX User Manual
GE Convection Oven SCB 1000 User Manual
Good Way Tech Network Card AP1305 User Manual