Hi Delta® - Type P
Job:
Engineer:
Contractor:
Prepared By:
Model:
Commercial Pool Heaters
Models 1802B-2342B
Date:
Indoor/Outdoor:
MBTUH Input:
Sealed Combustion Chamber
100% Factory Fire Tested
Efficiency: 85%
Minimum Non-condensing Inlet Temperature: 105°F
Thermal Shock Proof Heat Exchanger
Limited Twenty-year Thermal Shock Warranty
Limited Five-year Heat Exchanger Warranty
Diagnostic Center with Fault History
PolyTuf Powder Coated Cabinet
No Combustible Floor Shield Required
Fan-assisted
Non-ferrous Bypass
Patented Burner Security Blanket
Heat Exchanger
Gas Train
Options
ꢀ
ꢀ
Bronze Headers
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
Gas Pressure Regulators
C-6 Ignition Module, Manual Reset
D-21 TruSeal™ Direct Vent
Right Side
Left Side (Model 1802B
Only)
F-10 Low Water Cut-off, Remote
Probe
ASME Inspected and Stamped
160 PSIG Working Pressure
National Board Approved
Cupro Nickel Finned Tubing
ASME Steel Tube Sheet
Silicone High Temp O-Rings
125 PSIG ASME Pressure Relief Valve
Temperature and Pressure Gauge
Water Connections
Left – Standard
Right – Option A-6
Bronze Pump, 120V, 60Hz
Non-ferrous Pool Bypass
Safety Shut-off Valves
Firing Control Valves
On/Off Firing
Low Gas Pressure Switch, Manual
Fuel
Natural Gas
Propane Gas
Design Certified ANSI Z21.56/
CSA 4.7
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
S-2
Dual High Gas Pressure
Switches, Manual Reset
SureRack Kit, Zone III and IV
SureRack Add-on, Zone IV
ꢀ
X-1
X-2
Burner
Ultra-low NOx:
Less than 30 PPM
Y-241 Temperature Controller,
1-4 Stages
ꢀ
ꢀ
ꢀ
Regulatory Agency Requirements
G-1 CSD-1
Construction
ꢀ
ꢀ
Controls
Indoor/Outdoor Construction
Enclosed Front Controls
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
ꢀ
120V, 60Hz, 1∅ Power Supply
120/24V 60Hz Transformer
100% Shut-off/Lockout
Hot Surface Ignition Systems (2)
Remote Flame Sensors (2)
High Limit Control, Auto Reset
On/Off Power Switch
Manual Shut-off, Front-mounted
Flow Switch
Blocked Vent Pressure Switch
Combustion Air Proving Switches
Economaster Pump Time Delay
Poolstat
Venting
ꢀ
Vent Location
Top – Standard
Rear – Option D-14
Vent Termination Cap
Outdoor – Option D-11
Indoor, Horizontal –
Option D-15
ꢀ
Indoor, Vertical (by others)
Combustion Air
ꢀ
In-Line Filter Kit (TruSeal
only) – Option D-17
Air Intake Elbow –
Option D-16
L
W
Catalog No.: 6000.342B
Effective: 8-15-08
Replaces: 3-1-07
|
Raymarine Microphone 86075 2 User Guide
RCA Satellite Radio DRD212NW User Guide
Roadmaster Car Speaker RS630 User Guide
Ryobi Grinder AG451 User Guide
Ryobi Outdoor Trimmer RY52001, RY52001A User Guide
Salton Kitchen Utensil RHFS1 User Guide
Samsung Cooktop SCD103 215 User Guide
Samsung Printer M202x User Guide
Schumacher Battery Charger SE 1072 User Guide
Sears Fitness Equipment 831287724 User Guide